Omar SobhandClaude Fable 5 0b4f306ed1 rtx-fea: reduced Newmark (mor::dynamic) + the phase-4a offline replay — the ≥10x gate is REFUTED by measurement at the validated resolution
Performance Benchmarks / Run Benchmarks (push) Canceled after 0s
CI / Format Check (push) Canceled after 0s
CI / Clippy Check (push) Canceled after 0s
CI / Build (macos-latest) (push) Canceled after 0s
CI / Build (ubuntu-latest) (push) Canceled after 0s
CI / Test (macos-latest) (push) Canceled after 0s
CI / Test (ubuntu-latest) (push) Canceled after 0s
CI / Build CPU-Only (Explicit) (push) Canceled after 0s
CI / Python Bindings (maturin) (macos-latest) (push) Canceled after 0s
CI / Python Bindings (maturin) (ubuntu-latest) (push) Canceled after 0s
CI / WASM Build + Size Check (push) Canceled after 0s
CI / Distributed Training Tests (push) Canceled after 0s
CI / CI Success (push) Canceled after 0s
Documentation / Build API Documentation (push) Canceled after 0s
Documentation / Build User Guide (push) Canceled after 0s
The dynamic layer over ReducedNonlinearModel: reduced consistent mass
V'MV (full element sum, never ECSW-sampled — ECSW weights are trained
on internal-force virtual work and would conserve the wrong inertia),
reduced_force_and_jacobian exposed (solve() refactored onto it), and
ReducedNewmark mirroring NonlinearDynamicStepper::newmark_newton in
reduced coordinates (same predictor, residual, tangent shape; no
rescue ladder by design — a reduced Newton death is a finding).

TDD (tests/reduced_newmark.rs): identity-basis march reproduces the
full stepper to 2.4e-14 over 15 steps (both Newton loops tightened to
1e-10 so only solver rounding separates them); rigid-translation
reduced mass = rho*A to 1e-9; a 6-mode POD basis tracks its training
trajectory at 4.2e-4 rms against a 1.0e-4 projection floor.

Phase 4a (fsi3_ecsw_offline.rs, fsi3_reduced_newmark_replay,
env-gated): reduced Newmark replay of the harvested FSI3 trajectory at
record cadence (dt_rec = 5x march dt), driven by the recorded
end-of-step loads. Measured, m=12/20:

- COST (dt-independent, the verdict): 3,068/3,580 us/step at 4.6/5.0
  Newton iters — 2.0-2.3x the banded full-order structural step
  (7,200 us/pass, bandedlu_fsi3_ny62_t85). The >=10x gate needs
  <=720 us/step; one reduced eval alone costs ~640 us because phase 2
  refuted hyperreduction (every eval loops all 70 elements). The gate
  arithmetic is closed: reduced Newton needs >=2 evals, capping the
  ROM at ~5x. THE CAMPAIGN GATE (pinned cycle bands at >=10x
  structural speedup) CANNOT BE MET at the validated resolution.
- TRACKING at record cadence diverges in the release transient (dies
  t=4.35-4.45) — and the RTX_REPLAY_IDENTITY control dies EARLIER
  (t=4.13) in the exact subspace: the death is the 5x-coarse
  integration + aliased loads, NOT the reduction. The record-cadence
  replay cannot judge subspace dynamics; the projection floor
  (1.1e-3 at m=12) remains the honest subspace statement.

Campaign verdict to be recorded in omni-cortex in the pre-registered
words.